MIL-P-45042F
-
not greater than 1 hour. The meter shall 1 be sealed to prevent the entrance of
dust and moisture and shall 1 be mounted to withstand shock and vibration
generated by the machine.
3.5 Size and capacity. Unless otherwise specified (see 6.2), the size
and capacity of the machine shall meet the requirements of table I for the
size specified. Machine size and capacity shall be not less than the stated
requirements of the size ordered.
3.6 Phisical size limitations. When specified (see 6.2), the physical
length
size of the machine shall not exceed the height, width, and
restrictions specified by the procuring activity to ensure the machine will
fit in its future operating location.
3.7 Performance. The machine shall be capable ` of performing metal
fabricating operations of punching, coping, bar shearing, structural shape
shearing, and notching to conform with the requirements of table I. The
machine shall be capable of performing these operations on structural steel
workplaces having a 60,000 PSI minimum tensile strength.
3.7.1 Additional performance requirements. Performance features required
in addition to, or in lieu of, the requirements herein shall be as specified
and fully described (see 6.2).
3.8 Standard equipment. All standard equipment normally provided with
the manufacturer's commercial machine shall be furnished.
3.9 Optional and accessory equipment. Optional and accessory equipment
shall be furnished as specified (see 6.2). The equipment provided shall be
functional and compatible to the size machine specified in table X.
3.10 Repair parts. Required repair parts shall be furnished as spec-
ified (see 6.2).
3.11 Marking on instruments, control panels, charts, and plates. All
words on the machine including all instruments, control panels, control units,
charts, plates, and related attachments shall be in the English laguage.
contrasting
in boldface on a
Characters shall be permanently marked
background. All plates shall be corrosion resistant
When specified (see 6.2), a lubrica-
3.11.1 Lubrication plate or chart.
tion plate or chart shall be attached to each machine.
If a chart is
furnished it shall be placed in a transparent plastic folder, or permanently
sealed between clear plastic sheets. Unless otherwise specified (see 6.2) the
information provided on the chart or plate shall be as listed below:
Points of lubricant application
Type of lubricant
Servicing Interval
SAE number or military or Federal specification for each
lubricant (if applicable)