3.11.2 Namplate. A nameplate shall be securely attached to each
machine. Unless otherwise specified (see 6.2), the nameplate shall contain the
information listed below:
Nomanclature
Manufacturer's name
Manufacturer's model designation
Manufacturer's serial number
Power input (volts, total amps, phase, frequency)
Amp rating of largest rotor
Short circuit/over-current protection rating
Contract number or order number
National stock number or plant equipment code
Date of manufacture
3.12 Technical data. When technical data is required, it shall be
furnished in accordance with the requirements of the contract and shall be
printed in the English language.
Workmanship of the machine and its accessories shall
3.13 Workmanship.
meet all requirements specified herein.
QUALITY ASSURANCE PROVISIONS
4.
4.1 Responsibility for inspection. Unless otherwise specified in the
contract or purchase order, the contractor is responsible for the performance
of all inspection requirements (examinations and tests) as specified herein.
Except as otherwise specified in the contract or purchase order, the
contractor may use his own or any other facilities suitable for the
performance of
the inspection
requirements
herein,
unless
specified
disapproved by the Government. The Government reserves the right to perform
any inspections set forth in the specification where such inspections are
deemed necessary to ensure supplies and services conform to prescribed
requirements.
4.1.1 Responsibility for compliance. All items shall met all require-
ments of sections 3 and 5. The inspections set forth in this specification
shall become a part of the contract-m's overall Inspection system or quality
program. The absence of any inspection requirements in the specification
shall not relieve the contractor of the responsibility of ensuring that all
products or supplies submitted to the Government for acceptance comply with
all requirements of the contract. Sampling inspection, as part of manufac-
turing operations, is an acceptable practice to ascertain conformance to
requirements, however, this does not authorize submission of known defective
material, either indicated or actual, nor does it commit the Government to
accept defective material.
4.2 Classification of inspections.
The Inspection requirements specified
herein are classifi ed as follows: